Acta Scientific Medical Sciences (ASMS)(ISSN: 2582-0931)

Research Article Volume 9 Issue 11

Analysis of Four-Hours Active Sampling Using 90 mm Plates + LTHT

Ludovica Borghesi1, Marco Redaelli1 and Giovanni Abramo2*

1Microbiological Laboratory Technician, DMX Pharma, Italy
2Head of Microbiological Laboratory, DMX Pharma, Italy

*Corresponding Author: Giovanni Abramo, Head of Microbiological Laboratory, DMX Pharma, Italy.

Received: August 28, 2025; Published: October 14, 2025

Abstract

3) through a perforated lid. This study focuses on continuous active air sampling using 90 mm plates and Active Air Sampler (AAS) devices, in accordance with ISO 14698:1-2003. The aim of this study was to increase the sampling time from 2 to 4 hours and the air volume from 1 m3 to 2 m3. At the end of the aspiration process plates was examined morphologically, to assess potential dehydration, and microbiologically for growth promotion capability. The results obtained after 4 hours of operation and 2 m3 of sampled air showed no signs of dehydration, as no reduction in agar thickness was observed.

Furthermore, there was no impairment of the microbial growth or recovery properties. Therefore, the morphological integrity and nutritional characteristics of the plates remained unchanged, which was crucial for understating the impact of active sampling on the plates and for ensuring the reliability of microbiological data obtained during environmental monitoring.

In conclusion, the study met the acceptance criteria required for environmental monitoring, including: i) microbial growth compliant with incubation conditions on all plates; ii) recovery of microorganisms ranging between 50% and 200%; iii) absence of dehydration phenomena.

 Keywords: Environmental Monitoring; Active Air Sampling; Dehydration Phenomena; Growth Promotion; Recovery

References

  1. Gazzetta Ufficiale. Decreto Legislativo 9 aprile 2008, n. 81. Attuazione dell’articolo 1 della legge 3 agosto 2007 n. 123, in materia di tutela della salute e della sicurezza nei luoghi di Lavoro (2008).
  2. Sandle Tim. “Best practices in environmental monitoring” (2020).
  3. European Commision “Eudralex”. Good Manufacturing Practice (GMP) for Medicinal products for Human and Veterinary use. ddg1 d.6 (2012)860362. The Rules Governing Medicinal products in the European Union.
  4. Rajiv Kohli and Kashmiri L Mittal. Elsevier. “Developments in surface contamination and cleaning” (2013).
  5. Durivage Mark Allen. “The certified pharmaceutical GMP professional handbook”. Edited by Merl Allen Durivage, Second edition. ASQ Quality press, (2016).
  6. European Commision “Eudralex”. Annex 1. Manufacture of sterile Medicinal products (2022).
  7. Viani I., et al. “Passive air sampling: the use of the Index of microbial air contamination”. Acta Biomedicine 10 (2020): 91.
  8. Mohammed Seif El-Din Ashour., et al. “Microbiological Environmental Monitoring in Pharmaceutical Facility”. Egyptian Academic Journal of Biological Sciences 1 (2011): 63-74.
  9. Pasquarella C., et al. “The index of microbial air contamination”. Journal of Hospital Infection4 (2000).
  10. International Standard ISO 14698-1:2003. Cleanrooms and associated controlled environments – Biocontamination control.
  11. CACR, Clean air and Containment Review, 2021. Issue 46 Number two. ISSN 2042-3268.
  12. CACR, Clean air and Containment Review, 2020. Issue 42 Number 42. ISSN 2042-3268.
  13. Gedimias Mainelis. “Bioaereosol sampling: classical approaches, advances and perspectives”. 54.5 (2020).
  14. Whyte W. “Cleanroom Microbiology”. John Wiley & Sons, Southern Gate, United Kingdom (2010).
  15. USP, United States Pharmacopeia <1116>.
  16. Holbrook D. “Controlling contamination. The origins of clean room technology”. History and Technology3 (2009): 173-191.
  17. Bennet Bill and Graham Cole. “Pharmaceutical production: an engineering guide”. IchemE (2003).
  18. International Standard ISO 14644-1:2015. Cleanroom classification.
  19. American Pharmaceutical Review. “The continuous monitoring concept for pharmaceutical manufacturing”. americanpharmaceuticalreview.com. (2025-04-16).
  20. “Continuous and effective microbiological air monitoring in critical environments. A comparison of analytical methodologies”. PDA Journal of Pharmaceutical Science and Technology 74 (2020): 446-455.
  21. Eaton T., et al. “Recovery of microbial contamination with settle plates exposed in a unidirectional airflow workstation for 4 hours”. AstraZeneca, Macclesfield, UK | EJPPS | 271 (2022).
  22. Grzyb T and Sklodowska A. “Mechanisms of desiccation-associated damage”. Microorganisms 2 (2022): 432.
  23. Breeuwer P. “Adaptation of pathogenic microorganisms to dry conditions”. The microbiological safety of low water (2014): 37-48.

Citation

Citation: Giovanni Abramo., et al. “Analysis of Four-Hours Active Sampling Using 90 mm Plates + LTHT”.Acta Scientific Medical Sciences 9.11 (2025): 12-20.

Copyright

Copyright: © 2025 Giovanni Abramo., et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.




Metrics

Acceptance rate30%
Acceptance to publication20-30 days
Impact Factor1.403

Indexed In





Contact US